Implementation Guide for Astacus project
0.0.1 - ci-build France flag

Implementation Guide for Astacus project - Local Development build (v0.0.1) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Resource Profile: Astacus Laboratory Result Observation Profile ( Experimental )

Official URL: https://aphp.fr/fhir/fr/astacus/StructureDefinition/astacus-observation-lab Version: 0.0.1
Draft as of 2024-05-23 Computable Name: AstacusLaboratoryResultObservationProfile

Copyright/Legal: Used by permission of HL7 International, all rights reserved Creative Commons License

Astacus Laboratory Result Observation Profile is based upon the core FHIR Observation Resource, and, along with the Fr Core DiagnosticReport Profile for Laboratory Results Reporting. Laboratory results are grouped and summarized using the DiagnosticReport resource which reference Observation resources. Each Observation resource represents an individual laboratory test and result value, a “nested” panel (such as a microbial susceptibility panel) which references other observations, or rarely a laboratory test with component result values. The Fr Core Laboratory Result Observation Profile sets minimum expectations for the Observation resource resource to record, search, and fetch laboratory test results associated with a patient to promote interoperability and adoption through common implementation. It identifies which core elements, extensions, vocabularies and value sets SHALL be present in the resource when using this profile. It provides the floor for standards development for specific uses cases.

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from Observation

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..* Observation Measurements and simple assertions
... status S 1..1 code registered | preliminary | final | amended +
... Slices for category S 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by pattern:$this
.... category:Laboratory S 1..1 CodeableConcept Classification of type of observation
Required Pattern: At least the following
..... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
...... system 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... code 1..1 code Symbol in syntax defined by the system
Fixed Value: laboratory
... code S 1..1 CodeableConcept Laboratory Test Name
Binding: LOINCCodes (extensible): LOINC codes

... effective[x] S 0..1 dateTime, Period, Timing, instant Clinically relevant time/time-period for observation
... value[x] S 0..1 Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period Result Value
... dataAbsentReason S 0..1 CodeableConcept Why the result is missing

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Observation.codeextensibleLOINCCodes (a valid code from LOINC)
http://hl7.org/fhir/ValueSet/observation-codes
from the FHIR Standard
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* Observation Measurements and simple assertions
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?!N 0..* Extension Extensions that cannot be ignored
Slice: Unordered, Open by value:url
... status ?!SΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.

.... category:Laboratory S 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.



Required Pattern: At least the following
..... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
...... system 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... code 1..1 code Symbol in syntax defined by the system
Fixed Value: laboratory
... code SΣ 1..1 CodeableConcept Laboratory Test Name
Binding: LOINCCodes (extensible): LOINC codes

... subject SΣC 1..1 Reference(Astacus Cancer Patient Profile) Who and/or what the observation is about
ref-1: SHALL have a contained resource if a local reference is provided
... effective[x] SΣ 0..1 Clinically relevant time/time-period for observation
.... effectiveDateTime dateTime
.... effectivePeriod Period
.... effectiveTiming Timing
.... effectiveInstant instant
... value[x] SΣC 0..1 Result Value
.... valueQuantity Quantity
.... valueCodeableConcept CodeableConcept
.... valueString string
.... valueBoolean boolean
.... valueInteger integer
.... valueRange Range
.... valueRatio Ratio
.... valueSampledData SampledData
.... valueTime time
.... valueDateTime dateTime
.... valuePeriod Period
... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Observation.statusrequiredObservationStatus
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:LaboratorypreferredPattern: laboratory
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleLOINCCodes (a valid code from LOINC)
http://hl7.org/fhir/ValueSet/observation-codes
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* Observation Measurements and simple assertions
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension N 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... modifierExtension ?!N 0..* Extension Extensions that cannot be ignored
Slice: Unordered, Open by value:url
... identifier Σ 0..* Identifier Business Identifier for observation
... basedOn ΣC 0..* Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) Fulfills plan, proposal or order
ref-1: SHALL have a contained resource if a local reference is provided
... partOf ΣC 0..* Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Part of referenced event
ref-1: SHALL have a contained resource if a local reference is provided
... status ?!SΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.

... Slices for category S 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by pattern:$this
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


.... category:Laboratory S 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.



Required Pattern: At least the following
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
...... system 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... version 0..1 string Version of the system - if relevant
...... code 1..1 code Symbol in syntax defined by the system
Fixed Value: laboratory
...... display 0..1 string Representation defined by the system
...... userSelected 0..1 boolean If this coding was chosen directly by the user
..... text 0..1 string Plain text representation of the concept
... code SΣ 1..1 CodeableConcept Laboratory Test Name
Binding: LOINCCodes (extensible): LOINC codes

... subject SΣC 1..1 Reference(Astacus Cancer Patient Profile) Who and/or what the observation is about
ref-1: SHALL have a contained resource if a local reference is provided
... focus ΣC 0..* Reference(Resource) What the observation is about, when it is not about the subject of record
ref-1: SHALL have a contained resource if a local reference is provided
... encounter ΣC 0..1 Reference(Encounter) Healthcare event during which this observation is made
ref-1: SHALL have a contained resource if a local reference is provided
... effective[x] SΣ 0..1 Clinically relevant time/time-period for observation
.... effectiveDateTime dateTime
.... effectivePeriod Period
.... effectiveTiming Timing
.... effectiveInstant instant
... issued Σ 0..1 instant Date/Time this version was made available
... performer ΣC 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Who is responsible for the observation
ref-1: SHALL have a contained resource if a local reference is provided
... value[x] SΣC 0..1 Result Value
.... valueQuantity Quantity
.... valueCodeableConcept CodeableConcept
.... valueString string
.... valueBoolean boolean
.... valueInteger integer
.... valueRange Range
.... valueRatio Ratio
.... valueSampledData SampledData
.... valueTime time
.... valueDateTime dateTime
.... valuePeriod Period
... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


... note 0..* Annotation Comments about the observation
... bodySite 0..1 CodeableConcept Observed body part
Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

... method 0..1 CodeableConcept How it was done
Binding: ObservationMethods (example): Methods for simple observations.

... specimen C 0..1 Reference(Specimen) Specimen used for this observation
ref-1: SHALL have a contained resource if a local reference is provided
... device C 0..1 Reference(Device | DeviceMetric) (Measurement) Device
ref-1: SHALL have a contained resource if a local reference is provided
... referenceRange C 0..* BackboneElement Provides guide for interpretation
obs-3: Must have at least a low or a high or text
.... id 0..1 string Unique id for inter-element referencing
.... extension N 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... low C 0..1 SimpleQuantity Low Range, if relevant
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
.... high C 0..1 SimpleQuantity High Range, if relevant
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
.... type 0..1 CodeableConcept Reference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..* CodeableConcept Reference range population
Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


.... age C 0..1 Range Applicable age range, if relevant
rng-2: If present, low SHALL have a lower value than high
.... text 0..1 string Text based reference range in an observation
... hasMember ΣC 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Related resource that belongs to the Observation group
ref-1: SHALL have a contained resource if a local reference is provided
... derivedFrom ΣC 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Related measurements the observation is made from
ref-1: SHALL have a contained resource if a local reference is provided
... component Σ 0..* BackboneElement Component results
.... id 0..1 string Unique id for inter-element referencing
.... extension N 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... code Σ 1..1 CodeableConcept Type of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

.... value[x] Σ 0..1 Actual component result
..... valueQuantity Quantity
..... valueCodeableConcept CodeableConcept
..... valueString string
..... valueBoolean boolean
..... valueInteger integer
..... valueRange Range
..... valueRatio Ratio
..... valueSampledData SampledData
..... valueTime time
..... valueDateTime dateTime
..... valuePeriod Period
.... dataAbsentReason C 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


.... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Observation.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Observation.statusrequiredObservationStatus
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:LaboratorypreferredPattern: laboratory
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleLOINCCodes (a valid code from LOINC)
http://hl7.org/fhir/ValueSet/observation-codes
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiteexampleSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
from the FHIR Standard
Observation.methodexampleObservationMethods
http://hl7.org/fhir/ValueSet/observation-methods
from the FHIR Standard
Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
http://hl7.org/fhir/ValueSet/referencerange-meaning
from the FHIR Standard
Observation.referenceRange.appliesToexampleObservationReferenceRangeAppliesToCodes
http://hl7.org/fhir/ValueSet/referencerange-appliesto
from the FHIR Standard
Observation.component.codeexampleLOINCCodes (a valid code from LOINC)
http://hl7.org/fhir/ValueSet/observation-codes
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard

This structure is derived from Observation

Summary

Mandatory: 3 elements
Must-Support: 8 elements

Structures

This structure refers to these other structures:

Slices

This structure defines the following Slices:

  • The element 1 is sliced based on the value of Observation.category

Differential View

This structure is derived from Observation

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..* Observation Measurements and simple assertions
... status S 1..1 code registered | preliminary | final | amended +
... Slices for category S 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by pattern:$this
.... category:Laboratory S 1..1 CodeableConcept Classification of type of observation
Required Pattern: At least the following
..... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
...... system 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... code 1..1 code Symbol in syntax defined by the system
Fixed Value: laboratory
... code S 1..1 CodeableConcept Laboratory Test Name
Binding: LOINCCodes (extensible): LOINC codes

... effective[x] S 0..1 dateTime, Period, Timing, instant Clinically relevant time/time-period for observation
... value[x] S 0..1 Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period Result Value
... dataAbsentReason S 0..1 CodeableConcept Why the result is missing

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Observation.codeextensibleLOINCCodes (a valid code from LOINC)
http://hl7.org/fhir/ValueSet/observation-codes
from the FHIR Standard

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* Observation Measurements and simple assertions
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?!N 0..* Extension Extensions that cannot be ignored
Slice: Unordered, Open by value:url
... status ?!SΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.

.... category:Laboratory S 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.



Required Pattern: At least the following
..... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
...... system 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... code 1..1 code Symbol in syntax defined by the system
Fixed Value: laboratory
... code SΣ 1..1 CodeableConcept Laboratory Test Name
Binding: LOINCCodes (extensible): LOINC codes

... subject SΣC 1..1 Reference(Astacus Cancer Patient Profile) Who and/or what the observation is about
ref-1: SHALL have a contained resource if a local reference is provided
... effective[x] SΣ 0..1 Clinically relevant time/time-period for observation
.... effectiveDateTime dateTime
.... effectivePeriod Period
.... effectiveTiming Timing
.... effectiveInstant instant
... value[x] SΣC 0..1 Result Value
.... valueQuantity Quantity
.... valueCodeableConcept CodeableConcept
.... valueString string
.... valueBoolean boolean
.... valueInteger integer
.... valueRange Range
.... valueRatio Ratio
.... valueSampledData SampledData
.... valueTime time
.... valueDateTime dateTime
.... valuePeriod Period
... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.


doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Observation.statusrequiredObservationStatus
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:LaboratorypreferredPattern: laboratory
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleLOINCCodes (a valid code from LOINC)
http://hl7.org/fhir/ValueSet/observation-codes
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C 0..* Observation Measurements and simple assertions
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension N 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... modifierExtension ?!N 0..* Extension Extensions that cannot be ignored
Slice: Unordered, Open by value:url
... identifier Σ 0..* Identifier Business Identifier for observation
... basedOn ΣC 0..* Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) Fulfills plan, proposal or order
ref-1: SHALL have a contained resource if a local reference is provided
... partOf ΣC 0..* Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Part of referenced event
ref-1: SHALL have a contained resource if a local reference is provided
... status ?!SΣ 1..1 code registered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.

... Slices for category S 1..* CodeableConcept Classification of type of observation
Slice: Unordered, Open by pattern:$this
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


.... category:Laboratory S 1..1 CodeableConcept Classification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.



Required Pattern: At least the following
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
..... coding 1..* Coding Code defined by a terminology system
Fixed Value: (complex)
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
...... system 1..1 uri Identity of the terminology system
Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category
...... version 0..1 string Version of the system - if relevant
...... code 1..1 code Symbol in syntax defined by the system
Fixed Value: laboratory
...... display 0..1 string Representation defined by the system
...... userSelected 0..1 boolean If this coding was chosen directly by the user
..... text 0..1 string Plain text representation of the concept
... code SΣ 1..1 CodeableConcept Laboratory Test Name
Binding: LOINCCodes (extensible): LOINC codes

... subject SΣC 1..1 Reference(Astacus Cancer Patient Profile) Who and/or what the observation is about
ref-1: SHALL have a contained resource if a local reference is provided
... focus ΣC 0..* Reference(Resource) What the observation is about, when it is not about the subject of record
ref-1: SHALL have a contained resource if a local reference is provided
... encounter ΣC 0..1 Reference(Encounter) Healthcare event during which this observation is made
ref-1: SHALL have a contained resource if a local reference is provided
... effective[x] SΣ 0..1 Clinically relevant time/time-period for observation
.... effectiveDateTime dateTime
.... effectivePeriod Period
.... effectiveTiming Timing
.... effectiveInstant instant
... issued Σ 0..1 instant Date/Time this version was made available
... performer ΣC 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Who is responsible for the observation
ref-1: SHALL have a contained resource if a local reference is provided
... value[x] SΣC 0..1 Result Value
.... valueQuantity Quantity
.... valueCodeableConcept CodeableConcept
.... valueString string
.... valueBoolean boolean
.... valueInteger integer
.... valueRange Range
.... valueRatio Ratio
.... valueSampledData SampledData
.... valueTime time
.... valueDateTime dateTime
.... valuePeriod Period
... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


... note 0..* Annotation Comments about the observation
... bodySite 0..1 CodeableConcept Observed body part
Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

... method 0..1 CodeableConcept How it was done
Binding: ObservationMethods (example): Methods for simple observations.

... specimen C 0..1 Reference(Specimen) Specimen used for this observation
ref-1: SHALL have a contained resource if a local reference is provided
... device C 0..1 Reference(Device | DeviceMetric) (Measurement) Device
ref-1: SHALL have a contained resource if a local reference is provided
... referenceRange C 0..* BackboneElement Provides guide for interpretation
obs-3: Must have at least a low or a high or text
.... id 0..1 string Unique id for inter-element referencing
.... extension N 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... low C 0..1 SimpleQuantity Low Range, if relevant
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
.... high C 0..1 SimpleQuantity High Range, if relevant
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
.... type 0..1 CodeableConcept Reference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..* CodeableConcept Reference range population
Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


.... age C 0..1 Range Applicable age range, if relevant
rng-2: If present, low SHALL have a lower value than high
.... text 0..1 string Text based reference range in an observation
... hasMember ΣC 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Related resource that belongs to the Observation group
ref-1: SHALL have a contained resource if a local reference is provided
... derivedFrom ΣC 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Related measurements the observation is made from
ref-1: SHALL have a contained resource if a local reference is provided
... component Σ 0..* BackboneElement Component results
.... id 0..1 string Unique id for inter-element referencing
.... extension N 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... code Σ 1..1 CodeableConcept Type of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

.... value[x] Σ 0..1 Actual component result
..... valueQuantity Quantity
..... valueCodeableConcept CodeableConcept
..... valueString string
..... valueBoolean boolean
..... valueInteger integer
..... valueRange Range
..... valueRatio Ratio
..... valueSampledData SampledData
..... valueTime time
..... valueDateTime dateTime
..... valuePeriod Period
.... dataAbsentReason C 0..1 CodeableConcept Why the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... interpretation 0..* CodeableConcept High, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


.... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet / CodeURI
Observation.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Observation.statusrequiredObservationStatus
http://hl7.org/fhir/ValueSet/observation-status|4.0.1
from the FHIR Standard
Observation.categorypreferredObservationCategoryCodes
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.category:LaboratorypreferredPattern: laboratory
http://hl7.org/fhir/ValueSet/observation-category
from the FHIR Standard
Observation.codeextensibleLOINCCodes (a valid code from LOINC)
http://hl7.org/fhir/ValueSet/observation-codes
from the FHIR Standard
Observation.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard
Observation.bodySiteexampleSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
from the FHIR Standard
Observation.methodexampleObservationMethods
http://hl7.org/fhir/ValueSet/observation-methods
from the FHIR Standard
Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
http://hl7.org/fhir/ValueSet/referencerange-meaning
from the FHIR Standard
Observation.referenceRange.appliesToexampleObservationReferenceRangeAppliesToCodes
http://hl7.org/fhir/ValueSet/referencerange-appliesto
from the FHIR Standard
Observation.component.codeexampleLOINCCodes (a valid code from LOINC)
http://hl7.org/fhir/ValueSet/observation-codes
from the FHIR Standard
Observation.component.dataAbsentReasonextensibleDataAbsentReason
http://hl7.org/fhir/ValueSet/data-absent-reason
from the FHIR Standard
Observation.component.interpretationextensibleObservationInterpretationCodes
http://hl7.org/fhir/ValueSet/observation-interpretation
from the FHIR Standard

This structure is derived from Observation

Summary

Mandatory: 3 elements
Must-Support: 8 elements

Structures

This structure refers to these other structures:

Slices

This structure defines the following Slices:

  • The element 1 is sliced based on the value of Observation.category

 

Other representations of profile: CSV, Excel, Schematron